Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual
Page 161
Chapter 5 Power-saving Function (Automatic Servo-of
f and Full Servo Functions)
POWER CON
PCON-CA/CFA
153
[For Parameter No.39 = 0]
Operation of actuator
Positioning
operation
Automatic servo
OFF standby
Servo OFF
Positioning
operation
Servo Condition
ON
ON
OFF
ON
Completed Position No.
Output (Current position
number output)
PM1 to ** =0
(PE** = OFF)
PM1 to ** = Output
(PE** = ON)
PM1 to ** = 0
(PE** = OFF)
PM1 to ** = 0
(PE** = OFF)
Positioning Completion
Signal PEND
OFF
ON
OFF
OFF
Servo OFF Delay
Time
(Parameter No.36 to 37)
[For Parameter No.39 = 1]
Operation of actuator
Positioning
operation
Automatic servo
OFF standby
Servo OFF
Positioning
operation
Servo Condition
ON
ON
OFF
ON
Completed Position No.
Output (Current position
number output)
PM1 to ** = 0
(PE** = OFF)
PM1 to ** = Output
(PE** = ON)
PM1 to ** = 0
Output
(PE** = ON)
PM1 to ** = 0
(PE** = OFF)
Positioning Completion
Signal PEND
OFF
ON
ON
OFF
Servo OFF Delay
Time
(Parameter No.36 to 37)