Chapter 3 Operation

POWER CON

PCON-CA/CFA

116

[5] Multi-step pressing

„

Image diagram

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width

[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Transported

load

Stop

mode

0

1

0.00

250.00

0.20

0.20

0

0

0.10

0.00

0.00

0

0

0

0

2

50.00

250.00

0.20

0.20

30

0

20.00

0.00

0.00

0

0

0

0

3

50.00

250.00

0.20

0.20

50

0

20.00

0.00

0.00

0

0

0

0

4

„

Control method

After pressing, the pressing pressure can only be changed in the pressing state.

The method of controlling multi-step pressing is the same as that described in [3] Pressing

operation.

1) Set the weak pressing (30%) in position No.2 and perform the pressing operation.

2) If pressing complete signal PEND is turned ON, start the pressing operation with pressing

pressure (50%) greater than the first pressure set in position No.3.

In this particular operation, turn ON ST3 after completion of ST2, and turn OFF ST2 when

PEND is turned OFF. In usual case, do not turn ON two or more ST* signals simultaneously.

The position data in position No.3 should be the same as that in position No.2 except the

setting in “Pressing”.

3) To add a pressing step with another pressing pressure, add a sequence consisting of a

position number and a pressing operation.

Position No.1

Position No.2

Position No.3