POWER CON

PCON-CA/CFA

131

[3] Operation Mode (RMOD, RMDS)

Input

Output

PIO signal

RMOD

RMDS

{

: Available, u: Unavailable

Two operation modes are provided so that the operation by PIO signals does not overlap with

the operation by a teaching tool such as PC software through SIO (serial) communication.

The mode change is normally done by the operation mode setting switch on the front panel of

the controller.

AUTO··········Operation by PIO signals is valid.

MANU·········Operation through SIO (serial) communication is valid.

However, the controller is subject to link connection

(Note 1)

to connect with a teaching tool such

as PC software by using a SIO converter, the controller may be far apart from the teaching tool.

In such a case, the controller can be entered into the MANU mode by setting PIO signal RMOD

to ON.

Because the RMDS signal is set to ON with the MANU mode selected by using the signal,

make the operation sequence interlocked.

The table below lists the switches on the front panel, the modes selected by the RMOD signal

and the corresponding output states of the RMDS signal.

Note 1 For the details of the link connection, refer to “9.1 Way to Set Multiple Controllers with

1 Teaching Tool”.

{

: Selected or set to ON

Condition

Status

PIO Operation

Invalid

(Note 2)

{

{

{

{

u

u

u

u

Teaching tool such as

PC software

PIO Operation

Allowed

(Note 2)

u

u

u

u

{

{

{

{

AUTO

{

{

u

u

{

{

u

u

Switches on

front panel

MANU

u

u

{

{

u

u

{

{

PIO Input

RMOD

u

{

u

{

u

{

u

{

PIO Output

RMDS

u

{

{

{

u

{

{

{

PIO valid: , PIO invalid:z





z

z

z







Note 2 “PIO valid” or “PIO invalid” is the function to select a restriction while the teaching tool

such as PC software is connected.

 

Caution: (1) Note that selecting “PIO start enable” by using the teaching tool such as

PC software makes all PIO signals valid to enable operation however the

states of the switches and RMOD signal input may be. In this status, the

actuator may be started depending on the signals from PLC.

(2) If the teaching tool such as PC software is disconnected from the

controller, “PIO start enable” or “PIO start disable” holds the state selected

before. After teaching operation or debugging is terminated, select “PIO

start enable” and disconnect the teaching tool such as PC software from

the controller.

Operation by normal PIO