Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 24

Advertising
background image

POWER CON

PCON-CA/CFA

16

11) Brake Release Switch (BK RLS/NOM)

For the actuator equipped with a brake, the switch is used to release the brake forcibly.

BK RLS ····· Brake forcible release

NOM·········· Normal operation (brake is activated)

12) Power Supply Connector [Refer to 2.3.1 Wiring Layout of Power Supply Connector]

It is the connector for the power supply (for controller control power, actuator driving and

brake control power) and for the input of emergency status signal.

13) Fan Unit

It is a forced cooling unit dedicated for PCON-CFA Type.

14) Fan Unit Desorption Lever

When replacing the fan unit, pull the lever up and the fan unit can be taken out. After

replacing with a new unit, push the lever down to affix the unit.

Warning : Always set the switch to “NOM” in normal operation.

(Make sure the opportunity to put the switch to RLS side is the minimum

and is limited to when startup and adjustment. Make certain to set the

switch to NOM side in normal use.)

The brake would not work even with the servo OFF condition if the switch is

on the RLS side. In the vertical oriented mount, the work may drop and

cause an injury or the work to be damaged.