Chapter 3 Operation

POWER CON

PCON-CA/CFA

69

3) Velocity [mm/s]········· Set the velocity in the operation.

Do not attempt to input a value more than the maximum velocity

[refer to the caution note below] or minimum velocity

(Note 1)

.

(Note) The minimum velocity differs depending on the type of the

actuator. Refer to the values stated in the appendix in Chapter

9 or the following for the calculation.

Min. Speed [mm/

/

s^2] = Lead Length [mm] / No. of Encoder Pluses / 0.001[s]

4) Acceleration [G] ······· Set the acceleration at start.

5) Deceleration [G] ······· Set the deceleration at stop.

(Reference)How to set the acceleration is described below. The same idea

can be applied to the deceleration.

1G=9800mm/s

2

: Accelerated to 9800mm/s per second

0.3G: Accelerated to 9800mm/s × 0.3 = 2940mm/s per second

 

Caution: (1) Set the velocity, acceleration and deceleration so that they do not

exceed the rating values described in the brochure or the instruction

manual of the actuator. Failure to follow this may cause the life of the

actuator to be shortened extremely.

(2) If shocks and/or vibrations appear on the actuator and/or the work,

lower the acceleration and/or the deceleration. In such cases, do not

continue the use of the actuator, otherwise the product life may be

shortened extremely fast.

(3) If the payload is extremely lighter than the rated payload, increase

accel..., acceleration/deceleration to larger than their rated values to

shorten the tact time. Please contact IAI for the settings in such

situation. Inform us of the weight, shape and mounting method of the

work and the installation conditions of the actuator.

(4) For the actuator of gripper type, set the velocity, acceleration and

deceleration on the single finger basis. Note that the relative velocity,

acceleration and deceleration between both the fingers are as twice as

the setting values.

6) Pressing [%]············· Setting proper data here allows pressing to be done. Set a pressing

torque (limit current value) in %. If the value is set to 0, the normal

positioning operation is performed.

The speed for the pressing operation is set in Parameter No.34.

If the setting of 3) is lower than the pressing velocity, the pressing

process will be conducted with the velocity of 3).

Caution: If the pressing velocity is changed, the pressing force may differ from

that specified in 9.5 List of Specifications of Connectable Actuators.

When the pressing velocity is changed, make sure to measure the

actual pressing force before start using.

7) Threshold [%]··········· Set the threshold value of the pressing torque in %.

If the torque (load current) becomes larger than this setting value

during pressing, the detection signal is output. This feature is used to

monitor the load current and judge whether the operation is good or

not in such an operation as press fitting in pressing.

Velocity

Time

9800mm/s

1s

1G

2940mm/s

0.3G

Advertising