Chapter 7 I/O Parameter

POWER CON

PCON-CA/CFA

167

I/O Parameter List (Continued)

No.

C

at

eg

or

y

Name

Symbol

Unit

(Note1)

Input Range

Default factory

setting

for

Positioner

Mode

for Pulse

Train

Mode

Relevant

sections

140 B IP address

IPAD

0.0.0.0 to

255.255.255.255

Separate volume

{

{

Separate

volume

141 B Subnet mask

SNMK

0.0.0.0 to

255.255.255.255

Separate volume

{

{

Separate

volume

142 B Default gateway

DFGW

0.0.0.0 to

255.255.255.255

Separate volume

{

{

Separate

volume

143 B Overload level ratio

OLWL

%

50 to 100

100

{

7.2 [76]

144 B Gain scheduling upper limit

multiplying ratio

GSUL

%

0 to 1023

0

{

7.2 [77]

145 C GS velocity loop proportional gain

GSPC

1 to 30000

750

{

7.2 [78]

146 C GS velocity loop integral gain

GSIC

1 to 500000

4500

{

7.2 [79]

147 B Total movement count threshold

TMCT

Times

0 to 999999999

0 (Disabling)

{

7.2 [80]

148 B Total operated distance threshold

ODOT

m

0 to 999999999

0 (Disabling)

{

{

7.2 [81]

149 B Zone output changeover

FPIO

0: To change

1: Not to change

0

{

{

7.2 [82]

152 B High output setting

BUEN

0: Disabling

1: Enabling

0

{

7.2 [83]

153 B BU velocity loop proportional gain

BUPC

1 to 10000

200

{

7.2 [84]

154 B BU velocity loop integral gain

BUIC

1 to 100000

4000

{

7.2 [85]

155 A Absolute battery retention time

AIP

0: 20 days

1: 15 days

2: 10 days

3: 5 days

2

{

7.2 [86]

156 B Torque check/Light malfunction

output select

SLAL

0: Torque check

effective

1: Light malfunction

effective

0

{

{

7.2 [87]

159 B FB half direct mode speed unit

(Note 4)

FBVS

mm/s

(deg/s)

0: Units of 1mm/s

1: Units of 0.1mm/s

Separate volume

{

Separate

volume

Note 2 The setting values vary in accordance with the specification of the actuator. At shipment, the

parameters are set in accordance with the specification.

Note 4 These parameters are exclusively used for the field network type.

Caution: Make sure to set to “Positioner Mode” (No. 25 PIO Pattern = 0 to 5) when performing

an operation with using the serial communication.

If it happens to be in the “pulse train mode” by mistake, the controller may operate

erratically because it is operated according to the “pulse train mode” parameters.