3 pulse train control mode (for pulse train type), Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 137

Advertising
background image

Chapter 3 Operation

POWER CON

PCON-CA/CFA

129

3.3

Pulse Train Control Mode (for Pulse Train Type)

This controller can switch over the mode between positioner mode and pulse train control

mode with the parameters. In Pulse Train Mode, the actuator can be operated by the pulse train

output of the host controller (PLC) positioning control function. This operation mode is not to be

changed after the system is complete to be established or during an operation.

 

Caution: • In Pulse Train Control Mode, the operation is performed corresponding to the

input pulse.

Input Pulse Value

Ÿ

Moving distance

Input pulse frequency

Ÿ

Velocity

Change in Input Pulse Frequency Ÿ Velocity change and acceleration/deceleration

Do not use the actuator above the specifications for the commands of the

movement amount, acceleration and deceleration from the host controller (PLC).

Doing so may cause an abnormal noise or malfunction.

„

Main Functions

Function Name

Name

1 Dedicated home return signal

When this function (signal) is used, home return

(Note 1)

can be

performed without using a complex sequence or an external

sensor, etc.

2 Brake control function

Since the controller controls the brake, there is no need to

program a separate sequence.

The electromagnetic brake power is supplied to the controller

from a power supply different from the main power.

Accordingly, the electromagnetic brake can be released freely

after the main power has been cut off.

3 Torque limiting function

The torque can be limited (a desired limit can be set by a

parameter) using an external signal. When the torque reaches

the specified level, a signal will be output. This function

(signal) permits pressing and press fitting operations.

4 Position-command primary

filter function

Soft start and stop can be achieved even when the actuator is

operated in the command-pulse input mode where

acceleration and deceleration are not considered.

Note 1 In the pulse train control mode, even the actuator of absolute specification needs home return

because it operates as that of incremental specification.