Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 55

Advertising
background image

Chapter 2 Wiring

POWER CON

PCON-CA/CFA

47

3) PIO Pattern 2 ···············256-point mode (Number of positioning points : 256-point type)

“*” in codes above shows the signal of the active low. Processing occurs when an

input signal of the type is turned OFF. An output signal of the type is normally ON

in the power-on status and turned OFF at signal output.

Ɣ Use the attached cable for the I/O connection.

Model : CB-PAC-PIOƑƑƑ (ƑƑƑ indicates the cable length L. Example. 020 2m)

0V(NPN Type)

24V DC

Supply

1A

P24

PM1

1B

0V

Supply

24V DC(NPN Type)

24V DC(PNP Type)

2A

P24

PM2

2B

0V(PNP Type)

Command Position No.1

3A

PC1

PM4

3B

Completed Position No.1

Command Position No.2

4A

PC2

PM8

4B

Completed Position No.2

Command Position No.4

5A

PC4

PM16

5B

Completed Position No.4

Command Position No.8

6A

PC8

PM32
PM64

PM128

6B

Completed Position No.8

Command Position No.16

7A

PC16

7B

Completed Position No.16

Command Position No.32
Command Position No.64

Command Position No.128

8A

PC32
PC64
PC128

8B

Completed Position No.32
Completed Position No.64
Completed Position No.128

Brake Control Release

9A

BKRL

9B

Operation Mode Changeover

10A

RMOD

RMDS

10B

Home Return

11A

HOME

HEND

11B

Pause

12A

*STP

PEND

12B

Start

13A

CSTR

SV

13B

Reset

14A

RES

*EMGS

14B

Servo ON

15A

SON

*ALM

15B

16A

16B

17A

N

17B

18A

N

18B

19A

19B

20A

20B

PCON

PIO Connector

Position Zone/Zone 1
Operating Mode Status (Manual Mode)
Home Return Completion
Position Completion
Servo ON Status
Emergency Stop Status
Alarm

BR- 1

RD- 1

OR- 1

YW- 1

GN- 1

BL- 1
PL- 1

GY- 1

WT- 1

BK- 1

BR- 2

RD- 2

OR- 2

YW- 2

GN- 2

BL- 2
PL- 2

GY- 2

WT- 2

BK- 2

BR- 3
RD- 3
OR- 3
YW- 3
GN- 3
BL- 3
PL- 3
GY- 3
WT- 3
BK- 3
BR- 4
RD- 4
OR- 4
YW- 4
GN- 4
BL- 4
PL- 4
GY- 4
WT- 4
BK- 4

PZONE

/ZONE1

LOAD

/TRQS

/*ALML

Load Output Level Status

/Torque Level Status

/Light Error Alarm

Advertising