Chapter 7 I/O Parameter

POWER CON

PCON-CA/CFA

193

[87] Torque check/Light malfunction output select (Parameter No.156)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

156 Torque check/Light malfunction

output select

SLAL

0: Load judge

output or torque

level status signal

output

1: Output of battery

voltage drop

warning or

message-level

alarm

0

Load judge output (LOAD) or torque level status signal (TRQS) output can be changed to the

battery voltage drop warning (ALML) signal or an alarm (ALML) output that is message level.

[88] Selecting the Use of velocity loop proportional gain and velocity loop integrated gain.

Even though Velocity Loop Proportional Gain can be set to Parameter No.31, 145 and 153, and

Velocity Loop Integrated Gain to Parameter No.32, 146 and 154, the values to be effective

during an operation is just one of them. The following table shows which parameter number

becomes effective in each condition.

Effective Parameter Number

High Output Setting (Parameter No.152)

1 (Enable)

0 (Disable)

101 to

(Enable)

Parameter No.145, 146 Parameter No.145, 146

Gain Scheduling

(Parameter No.144)

to 100

(Disable)

Parameter No.153, 154

Parameter No.31, 32

[89] FB half direct mode speed unit (Parameter No.159)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

159 FB half direct mode speed unit

FBVS

mm/s

(deg/s)

0: Units of 1mm/s

1: Units of 0.1mm/s

0

These parameters are exclusively used for the field network type.

[Check the applicable instruction manual number in Chapter 4 Field Network, and refer to each

instruction manual.]