Pcon-ca/cfa, Power con, Moving complete startup – IAI America PCON-CA User Manual

Page 249: Chapter 9 appendix

Advertising
background image

Chapter 9

Appendix

POWER CON

PCON-CA/CFA

241

[8] Position 1 Operation Circuit

The main circuit is designed to process and manage signals “start” o “moving” o “positioning

complete” to move the actuator to position No.1.

STA R TL

PEND

RC Start

Display

AUX7

Position 1

Positioning

Start Pulse

AUX10

Position 1

Positioning

Start Check

Point

Positioning

Completion

AUX17

Position 3

Positioning

Complete

AUX6

Completed

Position 3

078

OUT1

IN13

OUT1

AUX9

a083 a087 b132

a135 b144 b151

a162

Auxiliary Position 1

Positioning Start

AUX9

Auxiliary Position 1

Positioning Start

STA R TL

PEND

RC Start

Display

AUX9

AUX 1 1

Position 1

Positioning

Complete

Point

Positioning

Completion

087

093

AUX10

AUX10

a084 a089 b093

Position 1

Positioning Start Check

Auxiliary

Position 1

Positioning

Start

Position 1 Positioning

Start Check

STA R TL

RC Start

Display

AUX10

AUX4

AUX12

AUX 1 1

AUX11

b 090 a095 b099

Position 1

Positioning Complete

Auxiliary

Position 2

Positioning

Start

Position 1

Positioning Complete

Position 1

Positioning

Start Check

Completed

Position 1

IN13

OUT1

OUT1

If 1 is not pulsed, 3 is reset

with 4 turned ON and 2 is

turned ON again.

Position 2 start signal

If movement is completed,

the moving circuit is turned OFF.

Turned OFF at start of next positioning

to position No.2.

Because any of start, moving or completion is set to

ON, it is possible to know the state in which the

actuator is stopped if it occurs.

If movement is started (PEND is

turned OFF), the start circuit is turned OFF.

Without home return, positioning to

position No.2 takes place after

home return

Moving

Complete

Startup

• Circuit

10

is designed to start positioning to position No.1 again after positioning to position No.3

is completed.

• If the “Operation” lamp goes off, the operation circuit is reset entirely. When the “Stop” button is

pushed, the actuator will stop at completion of the operation being executed. At emergency

stop, the actuator is stopped immediately (which is the function of PCON).