Pcon-ca/cfa, Power con, 3 circuit diagram – IAI America PCON-CA User Manual

Page 51

Advertising
background image

Chapter 2 Wiring

POWER CON

PCON-CA/CFA

43

2.1.3 Circuit Diagram

Sample circuit diagrams are shown below.

[1] Power Supply Connector (for power supply and emergency stop)

24V

0V

0V

0V

Emergency

Stop Reset

Switch

Emergency

Stop Switch

CR1

CR1

CR2

S1

S2

MPI

MPO

24V

EMG-

BKLS

S1

S2

MPI

MPO

24V

EMG-

BKLS

CR1

(Note 3)

CR1

(Note 4)

Brake forced

release switch

Brake forced

release switch

Power Supply

Connector

PCON-CA

Emergency-stop

Switch on the

Teaching Pendant

Control

power

supply

SIO Connector

(Note 1)

Power Supply

Connector

PCON-CA

SIO Connector

(Note 1)

Motor power supply

CR2

(Note 2)

CR2

(Note 2)

Emergency Stop Control Circuit

Brake Release Power Supply

(Note) When connecting actuator equipped with brake

supply 24V power to forcibly release the brake.

Note 1 : When the teaching pendant is not connected, S1 and S2 become short-circuited inside the

controller.

Note 2 : When the motor driving source is cut off externally for a compliance with the safety

category, connect a contact such as a contactor to the wires between MPI and MPO. [Refer

to Chapter 9 Appendix]

Note 3 : The rating for the emergency stop signal (EMG-) to turn ON/OFF at contact CR1 is 24V DC

and 10mA or less.

Note 4 : For CR1, select the one with coil current 0.1A or less.

Note 5 : When rebooting after shutting down, leave for 1sec or more.

Caution : If supplying power with using a 24V DC, having it turned ON/OFF, keep the 0V

connected and have the +24V supplied/cut (cut one side only).