Pcon-ca/cfa, Power con, 4] pio circuit – IAI America PCON-CA User Manual

Page 53

Advertising
background image

Chapter 2 Wiring

POWER CON

PCON-CA/CFA

45

[4] PIO Circuit



1) PIO Pattern 0 ·············Positioning Mode (Standard Type)

“*” in codes above shows the signal of the active low. Processing occurs when an

input signal of the type is turned OFF. An output signal of the type is normally ON

in the power-on status and turned OFF at signal output.

Ɣ Use the attached cable for the I/O connection.

Model : CB-PAC-PIOƑƑƑ (ƑƑƑ indicates the cable length L. Example. 020 2m)

0V(NPN Type)

24V DC

Supply

BR- 1

1A

P24

PM1

1B

BR- 3

0V

Supply

24V DC(NPN Type)

24V DC(PNP Type)

RD- 1

2A

P24

PM2

2B

RD- 3

0V(PNP Type)

Command Position No.1

OR- 1

3A

PC1

PM4

3B

OR- 3

Completed Position No.1

Command Position No.2

YW- 1

4A

PC2

PM8

4B

YW- 3

Completed Position No.2

Command Position No.4

GN- 1

5A

PC4

PM16

5B

GN- 3

Completed Position No.4

Command Position No.8

BL- 1

6A

PC8

PM32

6B

BL- 3

Completed Position No.8

Command Position No.16

PL- 1

7A

PC16

MOVE

7B

PL- 3

Completed Position No.16

Command Position No.32

GY- 1

8A

PC32

ZONE1

8B

GY- 3

Completed Position No.32

Brake Control Release

WT- 1

9A

BKRL

9B

WT- 3

Moving

Operation Mode Changeover

BK- 1

10A

RMOD

RMDS

10B

BK- 3

Zone

Home Return

BR- 2

11A

HOME

HEND

11B

BR- 4

Position Zone/Zone 2

Pause

RD- 2

12A

*STP

PEND

12B

RD- 4

Operating Mode Status (Manual Mode)

Start

OR- 2

13A

CSTR

SV

13B

OR- 4

Home Return Completion

Reset

YW- 2

14A

RES

*EMGS

14B

YW- 4

Position Completion

Servo ON

GN- 2

15A

SON

*ALM

15B

GN- 4

Servo ON Status

BL- 2

16A

16B

BL- 4

Emergency Stop Status

PL- 2

17A

N

17B

PL- 4

Alarm

GY- 2

18A

N

18B

GY- 4

WT- 2

19A

19B

WT- 4

BK- 2

20A

20B

BK- 4

PCON

PIO Connector

PZONE

/ZONE2

LOAD

/TRQS

/*ALML

Load Output Level Status

/Torque Level Status

/Light Error Alarm

Advertising