Pcon-ca/cfa, Power con, 3 generation of noise and/or vibration – IAI America PCON-CA User Manual

Page 212

Advertising
background image

Chapter 8

Troubleshooting

POWER CON

PCON-CA/CFA

204

8.2.3 Generation of noise and/or vibration

Situation

Possible cause

Check/Treatment

Generation of noise

and/or vibration from

actuator itself

Noise and vibration are generated by

many causes including the status of

load, the installation of the actuator, and

the rigidity of the unit on which the

actuator is installed.

Servo adjustment may improve the

situation.

[Refer to 7.3 Servo Adjustment.]

It may be improved with setting to

Full Servo Mode if the case occurs

during deceleration and stop.

[Refer to Chapter 5 Power-saving

Function]㩷

[In the case of Positioner Mode]

Situation

Possible cause

Check/Treatment

Vibrations of load

1) Acceleration/deceleration is set too

high.

2) The installation structure and/or the

installed load are easily affected by

acceleration/deceleration.

1) Decrease the settings of

acceleration/deceleration.

[In the case of Pulse Train Control Mode]

Situation

Possible cause

Check/Treatment

Vibrations of actuator or

load

Acceleration/deceleration is set too

high.

Decrease the setting of

acceleration/deceleration in the

host controller.

Generation of noise

during acceleration

The host controller has no

acceleration/deceleration function or

does not have acceleration/deceleration

function from speed 0.

(Some positioning units have

acceleration/deceleration function but

cannot use the function from speed 0.

Note this when you select a positioning

unit.)

[Refer to 7.3 Servo Adjustment

No.7]