Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 22

Advertising
background image

POWER CON

PCON-CA/CFA

14

1) Absolute Battery Connector [Refer to Chapter 6]

It is the connector to plug in the enclosed battery if applicable for Simple Absolute Type

(option).

2) Absolute Battery [Refer to Chapter 6]

It is enclosed if applicable for Simple Absolute Type (option).

It is used to retain the encoder information.

Use unit by affixing it on the side of PCON body with fabric hook-and-loop fastener or store it

Absolute Battery Unit (option).

3) Absolute Battery Status Indicator LED [Refer to Chapter 6]

It is equipped if applicable for Simple Absolute Type (option).

It displays the status such as battery charge condition and error generation.

{

: Illuminating × : OFF

LED

Operation status

RDY(GN)/

ALM(RD)

1 (GN/RD)

0 (GN/OR/RD)

Description

Ч

Ч

Ч

Control Power OFF

{

(GN)

{

(GN)

{

(Either color) Absolute Reset Complete

{

(GN)

{

(RD)

{

(Either color) Absolute Reset Incomplete

{

(RD)

{

(RD)

{

(Either color) Error occurred.

{

(Either color) { (Either color)

{

(GN)

Battery Fully Charged

{

(Either color) { (Either color)

{

(OR)

Battery Charging Operation

{

(Either color) { (Either color)

{

(RD)

Battery Disconnected

4) PIO Connector/Field Network Connector

PIO Type is equipped with the input and output signal connectors for control and Fieldbus

Network Type with connectors for each field network connection.

[Refer to 2.1.2 PIO Pattern Selection and PIO Signal or 2.2.2 I/O Signals in Pulse Train

Control Mode]

[For the details of the field network, refer to Chapter 4 and the instruction manual for each

field network.]

5) Controller Status Indicator LED

Following show the controller operation status:
{

: Illuminating × : OFF ڏ : Flashing

LED

Status of PIO Output Signal

SV (GN) ALM

(RD)

Operation status

SV Output

(Servo ON)

*ALM Output

(Note 1)

*EMGS

Output

(Note 1)

(Emergency

stop status)

Control Power OFF

Ч

Ч

Servo OFF

Alarm

(Operation Cancellation

Level or more)

OFF

OFF

OFF

Motor Driving Power

Supply OFF

×

{

In the Emergency Stop

OFF

OFF

ON

{

×

Servo ON

ON

ON

OFF

ڏ

×

During Automatic

servo-off

(Note 2)

OFF

ON

OFF

{

(OR)

During initialization after

power is supplied

OFF

OFF

OFF

Note 1 *ALM output is an active low signal that is turned on when in normal condition and

turned off when an error is generated.

Note 2 Signal during automatic servo-off : [Refer to Chapter 5]