Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 218

Advertising
background image

Chapter 8

Troubleshooting

POWER CON

PCON-CA/CFA

210

Alarm

Code Alarm Level

Alarm Name

Cause/Treatment

0A8

Unsupported

motor/encoder types

Cause

: The motor connected to the controller is not

applicable or the type of the encoder that the

motor is connected is not applicable.

Treatment : Please contact us if the alarm is issued even with

the applicable actuator and the same problem

happens again even after rebooting the power.

0B8

Cold start

Excitement detection

error

Cause

: In this controller, the excitation detection starts

when the servo is turned ON for the first time

after the power is supplied. The detection is not

finished after a certain time (set to Parameter

No.29) being passed.

1) Connection error or wire breakage of

motor/encoder cables.

2) Brake is not released (when equipped with a

brake).

3) Load to the motor is high due to external

force.

4) Power was turned on while touching to the

mechanical end.

5) The resistance in the actuator sliding

operation is large.

6) Parameter No.22 Home Return Offset was set

smaller than the initial value.

Treatment : 1) Check for the motor/encoder cable wiring

condition.

2) Supply 24V DC 150mA to the BKRLS terminal

on the power supply connector and if you can

see an improvement, it is considered the

controller failure. Please contact IAI.

3) Confirm that there is no error in the

mechanical part assembly condition.

4) Move the slider or the rod to a point where it

would not hit the mechanical end and reboot

the system.

5) If the loaded weight is within the allowable

range, turn the power OFF and check the

resistance in sliding operation by moving the

slider with hand.

6) For Simple Absolute Type, the excitation

detection is performed at the end of home

return operation. If the Parameter No.22

Home Return Offset is set smaller than the

initial setting, the actuator interferes with the

mechanical end and excitation detection

cannot be performed properly.

0BA

Home sensor

non-detection

Cause

: This indicates that the home-return operation of

the actuator equipped with origin sensor (option

except rotary actuator) is not completed in

normal condition.

1) Work is interfering with peripheral equipment

in the middle of home return.

2) Large slide resistance of the actuator itself

3) Installation failure, breakdown or

disconnection of the home sensor

Treatment : In the case that the work does not interfere with

anything, the cause 2) or 3) is supposed. In such

case, please contact IAI.

0BE

Operation

release

Home return timeout

Cause

: Home return does not complete after elapse of a

certain period after the start of home return.

Treatment : This error does not occur in normal operation.

The combination of the controller and actuator

may be incorrect. Please contact IAI.