Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 199

Advertising
background image

Chapter 7 I/O Parameter

POWER CON

PCON-CA/CFA

191

[78] GS velocity loop proportional gain (Parameter No.145)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

145 GS velocity loop proportional gain GSPC

1 to 30000

750

When the gain scheduling upper multiplying rate (Parameter No.144) is set to 101 or more, this

parameter setting becomes effective for Velocity Loop Proportional Gain.

[Refer to the 7.2 [24] Velocity loop proportional gain for the details]

[Reference Item] 7.2 [88] Selecting the Use of velocity loop proportional gain and velocity loop

integrated gain.

[79] GS velocity loop integral gain (Parameter No.146)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

146 GS velocity loop integral gain

GSIC

1 to 500000

4500

When the gain scheduling upper multiplying rate (Parameter No.144) is set to 101 or more, this

parameter setting becomes effective for Velocity Loop Integrated Gain.

[Refer to the 7.2 [25] Velocity loop integral gain for the details]

[Reference Item] 7.2 [88] Selecting the Use of velocity loop proportional gain and velocity loop

integrated gain.

[80] Total movement count threshold (Parameter No.147)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

147 Total movement count threshold

TMCT

Times

0 to 999999999

0(Disabling)

A light error alarm is generated when the total movement count exceeds the value set to this

parameter.

The judgment would not be made if the value is set to 0.

[81] Total operated distance threshold (Parameter No.148)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

148 Total operated distance threshold

ODOT

m

0 to 999999999

0(Disabling)

A light error alarm is generated when the total operation distance exceeds the value set to this

parameter.

The judgment would not be made if the value is set to 0.

[82] Zone output changeover (Parameter No.149)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

149 Zone output changeover

FPIO

0: Not to change

1: To change

0

When there is PZONE signal to the current PIO pattern or the Fieldbus Operation Mode and no

ZONE1 or ZONE2 signal, it is available to change the PZONE signal to either ZONE1 or

ZONE2 signal.

(Note 1) ZONE1 signal is assigned prior to ZONE2 signal.

(Note 2) It would not function in the pulse train mode.

(Note 3) In the case there is no PZONE signal in PIO patterns, or both ZONE1 and ZONE2

signals exist, the setting would be invalid.