(2) Multi-Rotation Specification

1) Once the home-return command is issued, the actuator rotates in CCW (counterclockwise)

direction from the view point of the load side. The velocity is 20deg/s.

2) Home sensor turns ON.

3) Starts reversed rotation.

4) Goes back to a point exceeded the home sensor detection range, and confirms the home

sensor is turned OFF.

5) Starts reversed rotation.

6) Confirms the home sensor gets turned ON again.

7) Goes to a point exceeded the home sensor detection range on the opposite side of the

home position, and confirms the home sensor is turned OFF.

8) Starts reversed rotation.

9) Confirms the home sensor turns ON.

10) Goes to a point exceeded the home sensor detection range on the home position side, and

confirms the home sensor is turned OFF.

11) Based on the result gained from 6), 7), 9) and 10), the center of the home sensor detection

range is calculated.

12) Moves for the amount set in Parameter No.22 “Home return offset level” from the position

of 11), and stops at the home position.

Caution: The operation of the reversed rotation type should be in the reversed way.

Make sure to refer to Section 7.2 [16] when a change to Parameter No.22

“Home return offset level” is required.