Pcon-ca/cfa, Power con, 4] tension operation – IAI America PCON-CA User Manual

Page 122: Chapter 3 operation, Image diagram

Advertising
background image

Chapter 3 Operation

POWER CON

PCON-CA/CFA

114

[4] Tension Operation

„

Image diagram

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width

[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Transported

load

Stop

mode

0

1

100.00

250.00

0.20

0.20

0

0

0.10

0.00

0.00

0

0

0

0

2

80.00

250.00

0.20

0.20

50

0

–50.00

0.00

0.00

0

0

0

0

3

„

Control method

The method of controlling the tension operation is the same as that described in [3] Pressing

operation. The control method is explained below by using the sample position table shown

above.

1) Position No.2 indicates the settings of tension operation. The settings of “Position” and

“Positioning width” show the tension start position and the tension quantity, respectively.

Attach – (negative sign) to the tension quantity. Specify the upper limit of the torque

required for tension in percent (limited current value) in “Pressing”. The speed,

acceleration, and deceleration are the conditions of positioning to the coordinate value

(80mm) set in “Position”.

2) Position No.1 indicates the tension start preparation position. Specify a value larger than

the coordinate value at which the tension provided by position No.2 ends (80 – 50 = 30mm)

in “Position”.

Position No.1

Position No.2

ST*

ST*

ST*: Start position

Tension Operation

Approach Operation

Tension Operation

Tension start position

80mm

Temsion end position

80 – 50 = 30mm

Advertising