Starting procedures, Pcon-ca/cfa, Power con – IAI America PCON-CA User Manual

Page 27: Positioner mode

Advertising
background image

POWER CON

PCON-CA/CFA

19

Starting Procedures

1. Positioner Mode

When using this product for the first time, make sure to avoid mistakes and incorrect wiring by

referring to the procedure below. “PC” stated in this section means “PC software”.

ω

Yes

No ψ

ω

ψ

No ψ

Contact us or our distributor.

ω

Yes

No ψ

ψ

Check Item

Is the Controller Status

Display LED turned OFF?

Connect the teaching tool

such as PC to confirm the

content of alarm and have

an appropriate treatment.

Servo ON

Turn the servo ON with the operation on the teaching tool such as PC.

Check Item

Is the Controller

Status Display

LED turned ON in

green [SV]?

Safety Circuit Check

Does the emergency stop circuit (drive cutoff circuit) work properly and turn

the servo OFF?

Check the emergency stop circuit.

Target Position Setting

Set the target position in “Position” Box in each position table.

Perform a home-return operation first when Direct Teaching is to be performed. When moving the actuator manually, set the

Brake Release Switch to “BK RLS” side for the brake equipped type. Put the switch back after the setting is complete.

ψ

No ψ

ω

Yes

Safety Speed Setting

Set the Parameter No.35 if necessary.

The safety speed is set to 100mm/s or less at the delivery.

ω

Test Run Adjustment 1

Check the operation without mounting a

work and set the safety speed invalid on

the teaching tool such as PC, and then

check the operation with a work mounted.

Check if there is any problem with the

installation of the actuator and the condition of

the actuator use exceeds the ranges of the rated

values.

Adjust the servo if necessary.

Power Supply and Alarm Check

Connect a teaching tool such as PC, turn the

operation mode setting switch to “MANU” side and

turn the power ON for unit.

Select [Teaching Mode 1 Safety Speed Activated /

PIO Operation Invalid] in the teaching tool.

If an alarm is

generated, connect

the PC or teaching

pendant and check

the content of the

alarm to have the

right treatment.

ω

Yes

φ

Yes

Test Run Adjustment 2

1) Set the operation mode setting switch to “AUTO”.

2) Output the operation command from PLC to the controller and check the system operation.

Check Item

Any vibration or

abnormal noise?

No ψ

ω

Yes

Check of Packed Items

Are there all the delivered items?



Caution To ensure safety, it is recommended

that safety speed be enabled during

initial movements.

Installation and Wiring [Refer to Chapter 1, 2.1, 2.3]

Perform the installation of and wiring for the actuator and

controller.

Caution

Please perform this process with the actuator away from the mechanical end or

interfering subjects as much as possible.

Put the actuator away if it interferes with surroundings. It may generate an alarm if the

actuator hit the mechanical end or interfering subjects when the servo is turned ON.

The slider may get slightly dropped by self-weight if servo ON and OFF is repeatedly

performed at the same position. Be careful not to pinch the hand or damage the work.

Warning In the case the actuator is installed in vertical orientation and put the brake release switch to [BK RLS] side, be

careful not to drop it with self-weight and pinch your hand or damage the work.

PIO Pattern Settings

Set the used PIO pattern to Parameter No.25.

Point Check Item

• Is frame ground (FG) connected?

• Has the noise countermeasure been taken?

Advertising