Chapter 5 Power-saving Function (Automatic Servo-of

f and Full Servo Functions)

POWER CON

PCON-CA/CFA

151

Chapter 5 Power-saving Function (Automatic Servo-off and Full

Servo Functions)

This controller possesses Automatic Servo-off and Full Servo functions to reduce the power

consumption while the actuator is stopped. Read the description in this chapter carefully to

save power so that the controller can be operated safely.

Automatic Servo-off function automatically turns the servo OFF in certain time after positioning

process is finished. The next positioning command is issued to turn the servo ON automatically

and achieve the positioning. No holding current flows in the stop state to allow the power

consumption to be saved.

3 types of patterns can be set for the time since positioning complete until servo turned OFF,

and either one can be selected.

In the Full Servo Function, it is able to reduce the power consumption by controlling the pulse

motor which consumes comparatively high current during a stop.

For the power saving function, which of Parameter No.53 or “Stop Mode” in the position table is

to be used is determined by the actuator condition. The details are shown below.

Setting

Status

PIO Pattern 0 to 4

PIO Pattern 0 to 5

Standby after home return

is complete

(Positioning to the target

point is not done)

Power saving function executed

with the values set in Parameter

No.53 (Stop Mode of the

position number is invalid)

Standby with the servo

turned ON after the power

is supplied (Positioning to

the target point is not

done)

Power saving function executed

with the values set in Parameter

No.53 (Stop Mode of the

position number is invalid)

Standby after the

positioning is complete to

the target position set in

the position table

Power saving function executed with the values set in “Stop

Mode” in each position number (Setting of Parameter No.53 is

invalid)

 

Warning: Do not use this function if the automatic servo OFF is followed by pitch feed

(relative movement).

Servo ON/OFF may cause slight position shift to occur. If position shift occurs

due to external force during servo OFF, positioning to the correct position is

disabled. It is because pitch feed is operated based on the position at start

used as the base point.

 

Caution: Automatic Servo-off Function is not effective while in pressing operation. Do

not use. It becomes effective at completion of positioning. In pressing, the

function becomes effective only when miss-pressing occurs (the status at the

completion of operation without pressing is the same as that at the

completion of positioning).

No retaining torque is provided in automatic servo-off. The actuator can

move with an external force. Pay attention to the interference to the

peripherals and the safety in the installation.