Chapter 9

Appendix

POWER CON

PCON-CA/CFA

223

9.2

Conformity to Safety Category

In this section shows an example of a circuit using the dedicated teaching pendant. However, it

is not possible for us to check the conformity of our product to the condition of your system.

Therefore, it is necessary that the user construct the circuit considering the condition of use and

the categories to be applied.

[1] System Configuration

In the case it is necessary to construct a system complying with Safe Category (ISO12100-1),

use the following teaching pendant.

(1) CON-PGA (Touch Panel Teaching)

Also, TP adapter (Model : RCB-LB-TG) is required.

The system can conform to up to safety category B to 4 (ISO12100-1) by changing connections

of system I/O connectors.

PCON

Controller / TP Adaptor

Connection Cable

Model : CB-CON-LB005

Controller

Connecting

Connector

TP Adaptor "RCB-LB-TG"

Touch Panel Teaching “CON-PGA”

Teaching Pendant

Connecting Connector

Safety Circuit

System I/O Connector

(The front (ENB*) is the lower side

and the back (EMG*) is upper side.)

Dummy plug “DP-4”

(Connect this when the teaching

tool is not connected. Without this,

the emergency stop condition

cannot be released.)

Please prepare

separately.