Fabric os system messages, Ag messages, Ag-1001 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 153: Ag-1002, Chapter 5, Chapter

Advertising
background image

Fabric OS Message Reference

131

53-1003140-01

Chapter

5

Fabric OS System Messages

AG Messages

AG-1001

Message

N_Port ID virtualization (NPIV) is not supported by fabric port connected to port

<port number>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the N_Port ID virtualization (NPIV) capability is not supported by the fabric port to which
the Access Gateway is connected.

Recommended

Action

Execute the portCfgNpivPort command to enable NPIV capability on the port connected to the
Access Gateway.

Some blades and ports in a switch may not support NPIV. NPIV functionality cannot be enabled
on such ports and they will not respond to NPIV requests. Refer to the Access Gateway
Administrator's Guide
for specific AG-compatibility requirements.

On non-Brocade switches, refer to the manufacturer's documentation to determine whether
the switch supports NPIV and how to enable NPIV on these types of switches.

AG-1002

Message

Unable to find alternate N_Port during failover for N_Port <port number>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that no other N_Port is configured or the fabric was unstable during failover.

Recommended

Action

Check whether an alternate N_Port is configured using the portCfgShow command.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

Advertising