Zeus-1016, Zeus-1028 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 985

Advertising
background image

Fabric OS Message Reference

963

53-1003140-01

ZEUS-1016

5

ZEUS-1016

Message

Port is faulted due to port re-initialization failure on internal Port S<slot

number>,P<port number>(<blade port number>) with reason <port fault reason>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified port failed due to port re-initialization failure.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

ZEUS-1028

Message

Detected excessive Link resets on the port in a second. Slot <slot number>, Port

<port number>(<blade port number>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the port received excessive link resets from peer port within 1 second and that exceeded
threshold.

Recommended

Action

When this error is observed persistently, change the small form-factor pluggable (SFP) transceiver or
cable on the peer port to which this port is connected.