724

Fabric OS Message Reference

53-1003140-01

PS-1009

5

PS-1009

Message

Failed to add the device updates in condb database.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the fabric has more than the allowed number of devices.

Recommended

Action

Reduce the number of devices configured in the fabric to be within the allowed limit. The maximum
number of devices that can be configured in a fabric is 940.

PS-1010

Message

Removed <Toptaker mode> Top Talker on port <Port no>. Reason: <Reason>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that Top Talker on the specified port has been removed due to memory allocation failure.

Recommended

Action

Install Top Talker again on the specified port using the perfttmon --add command.