227

53-1003140-01

CCFG-1011

5

CCFG-1011

Message

Linecard configuration mismatch on slot <slot>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the inserted line card is different from the pre-configured line card on the specified slot.

Recommended

Action

Execute the no linecard command to remove the line card configuration.

CCFG-1012

Message

Blade in slot <slot> failed to reach ONLINE state within <timeout> seconds after

receiving system ready.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the blade in the specified slot has failed to come online within the specified timeout interval
after receiving the system ready event.

Recommended

Action

Execute the slotPowerOff and slotPowerOn commands on the specified slot to bring the blade online.

CCFG-1013

Message

<mode_command>.

Message Type

AUDIT

Class

CFG

Severity

INFO

Probable Cause

Indicates that the switch state has changed.

Recommended

Action

No action is required.