CVLM-1004

5

CVLM-1004

Message

Crypto device configuration between local switch (<local switch WWN>) and peer

(<peer switch WWN>) is out of sync. New encryption session is not allowed.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that encryption engine nodes in the cluster encryption group have different configurations.

Recommended

Action

Synchronize the configuration in the cluster group using the cryptocfg --commit command.

CVLM-1005

Message

Crypto service is <status> on the switch.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the crypto service is enabled or disabled on the switch.

Recommended

Action

No action is required.

CVLM-1006

Message

Crypto device <device WWN> in target container <container name> is not in AD0.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the crypto device in the crypto target container is not in root zone database (AD0).

Recommended

Action

Use the ad command to move the crypto device into AD0.

CVLM-1007

Message

Redirect zone update failure. Status is <status>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the redirect zone update has failed.