Fabric OS Message Reference

53-1003140-01

SWCH-1019

5

SWCH-1019

Message

Device <wwn name of device> tries to FLOGI, reject FLOGI as persistent PID is set

on device and port <port number> has user area <area> bound to it.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates a WWN-PID and port address binding collision.

Recommended

Action

The persistent PID is set on the device and the requested area cannot be assigned because the port it is
trying to log in through has a different area bound to it. Remove the WWN-PID binding using the
wwnaddress --unbind command or remove the port address binding using the portaddress --unbind
command and then re-enable the port.

SWCH-1020

Message

HA state out of sync: Standby CP (ver = <standby SWC version>) does not support

QoS links to AG(Active CP version = <active SWC version>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the standby control processor (CP) does not support links to Access Gateway running
quality of service (QoS).

Recommended

Action

Load a firmware version on the standby CP that supports QoS links to Access Gateway by using the
firmwareDownload command.

SWCH-1021

Message

HA state out of sync: Standby CP (ver = <standby SWC version>) does not support

Dynamic area on default switch (Active CP version = <active SWC version>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the standby control processor (CP) does not support dynamic area on the default switch.

Recommended

Action

Load a firmware version on the standby CP that supports dynamic area on the default switch by using the
firmwareDownload command.