Sec-1183, Sec-1184, Sec-1185 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 815

Advertising
background image

Fabric OS Message Reference

793

53-1003140-01

SEC-1183

5

Recommended

Action

No action is required.

SEC-1183

Message

Policy to binary conversion error: Port <port number> is out range.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a security database conversion has failed because of an invalid value.

Recommended

Action

Retry the command with a valid value.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

SEC-1184

Message

<Security server (RADIUS/LDAP/TACACS+)> configuration change, action <action>,

server ID <server name>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the specified action is applied to the specified remote authentication dial-in user service
(RADIUS/LDAP/TACACS+) server configuration. The possible actions are ADD, REMOVE, CHANGE,
and MOVE.

Recommended

Action

No action is required.

SEC-1185

Message

<action> switch DB.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the switch database was enabled or disabled as the secondary authentication, authorization,
and accounting (AAA) mechanism when remote authentication dial-in user service
(RADIUS/LDAP/TACACS+) is the primary AAA mechanism.

Recommended

Action

No action is required.

Advertising