Fabric OS Message Reference

209

53-1003140-01

C2-1019

5

C2-1019

Message

S<slot number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached

type = 0x<chip error type>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an internal error is observed in the application-specific integrated circuit (ASIC) hardware
that may degrade the data traffic.

Recommended

Action

Restart the system at the next maintenance window.

C2-1020

Message

S<slot number>,P<port number>(<blade port number>): Internal CRC with good EOF

errors were observed, continuing monitoring. current:0x<last_crc_good_eof_cnt>,

last:0x<total_crc_good_eof_cnt> thresh1:0x<threshold_used>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates some CRC errors detected on backend link by hardware, typically applications are not affected
at this low count.

Recommended

Action

No action is required.

C2-1025

Message

S<slot number>,P<port number>(<blade port number>): Extra credit on

F_port:ftx=<ftx> curr_cred=<current credits> actual_cred=<actual credits>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the device is returning the wrong number of receiver-ready (R_RDY) frames.

Recommended

Action

When this error is observed persistently, replace the device.