Ag-1003, Ag-1004, Ag-1005 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 154

Advertising
background image

132

Fabric OS Message Reference

53-1003140-01

AG-1003

5

AG-1003

Message

Unable to failover N_Port <port number>. Failover across different fabric is not

supported.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the failover does not get blocked between two fabrics, although it is not a supported
configuration.

Recommended

Action

Configure two or more N_Ports to connect to the same fabric; then execute the ag --failoverenable
command to enable failover on these N_Ports.

AG-1004

Message

Invalid response to fabric login (FLOGI) request from the fabric for N_Port <port

number>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the
specified N_Port.

Recommended

Action

Check the configuration of the fabric switch.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

AG-1005

Message

FDISC response was dropped because F_Port <port number> is offline.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the F_Port connected to the host is offline, which caused the Fabric Discovery (FDISC)
response to drop.

Recommended

Action

Check the configuration of the host connected to the specified F_Port.