Rpcd-1004, Rpcd-1005, Rpcd-1006 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 765: Rpcd-1007

Advertising
background image

Fabric OS Message Reference

743

53-1003140-01

RPCD-1004

5

RPCD-1004

Message

Invalid certificate file. Secure RPCd is disabled.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates the Secure Sockets Layer (SSL) certificate file has been corrupted.

Recommended

Action

To enable remote procedure call daemon (RPCD) in secure mode, install a valid SSL certificate on the
switch.

RPCD-1005

Message

Missing private key file. Secure RPCd is disabled.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates the private key file is missing.

Recommended

Action

Run the secCertUtil command to install a valid private key file.

RPCD-1006

Message

Permission denied accessing private key file. Secure RPCd is disabled.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates the private key file configured on the switch could not be accessed because the root did not
have read-level access.

Recommended

Action

Change the file system access level for the private key file to have root read-level access.

RPCD-1007

Message

Invalid private file. Secure RPCd is disabled.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates the private key file has been corrupted.

Advertising