Fabric OS Message Reference

921

53-1003140-01

SYSM-1004

5

SYSM-1004

Message

Failed to retrieve current chassis configuration option, ret=<Unknown>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates there was a failure to read configuration data from the World Wide Name (WWN) card.

Recommended

Action

Verify that the WWN card is present and operational and the affected control processor (CP) is properly
seated in its slot.

SYSM-1005

Message

CP blade in slot <Slot number> failed to retrieve current chassis type.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates there was a failure to read the chassis type from the system.

Recommended

Action

Verify the control processor (CP) blade is operational and is properly seated in its slot.

SYSM-1006

Message

CP blade in slot <Slot number> is incompatible with the chassis type.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates this chassis type is not compatible with the control processor (CP) blade.

Recommended

Action

Use the CP blade on a compatible chassis.