Fabric OS Message Reference

875

53-1003140-01

SSMD-1004

5

SSMD-1004

Message

Failed to unlock semaphore mutex: (<function name>).

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified function failed to unlock the mutex (semaphore).

Recommended

Action

Restart or power cycle the switch.

SSMD-1005

Message

SSM start up failed.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that Data Center Ethernet (DCE) SSM encountered an unexpected severe error during basic
startup and initialization.

Recommended

Action

Restart or power cycle the switch.

If the problem persists, download a new firmware using the firmwareDownload command.

SSMD-1006

Message

Error while configuring ACL <ACL name> on interface <Interface name>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that an error occurred while programming a Ternary Content Addressable Memory (TCAM)
entry on the specified interface.

Recommended

Action

Try again after some time. If the problem persists, execute the supportSave command and then restart
or power cycle the switch.