Fabric OS Message Reference

949

53-1003140-01

XTUN-1009

5

XTUN-1009

Message

FCIP OSTP <Number of FCP write commands that were purged> Write blocks purged due

to PLOGI slot=<FX8-24 Slot number (0 for 7800 or 7840)> DP=<FX8-24/7840 DP number

(or 0 if 7800)> SFID=<SFID of the initiator> DFID=<DFID of the tape device>

SID/DID/Lun=0x<SID of the initiator>/<DID of the tape device>/<The tape device LUN

number>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that more than one outstanding write command that were purged due to the receipt of a new
PLOGI sequence. This can indicate missing blocks on the currently mounted tape. If the tape job
resumed after this error, you must confirm the integrity of the data on the tape.

Recommended

Action

Contact your vendor's customer support for assistance.

XTUN-1996

Message

FTRACE buffer <FTRACE Trace Buffer Number> on slot <FX8-24 Slot Number (0 for 7800

and 7840)> DP <FX8-24/7840 DP Number (or 0 if 7800)> has been cleared.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a CLI command or supportSave operation freed the trace buffer back into the FTRACE
free pool.

Recommended

Action

No action is required.

XTUN-1997

Message

FTRACE buffer <FTRACE Trace Buffer Number> on slot <FX8-24 Slot number (0 for 7800

or 7840)> dp <FX8-24/7840 DP number (or 0 if 7800)> has been triggered.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a programmed trigger event has been detected.

Recommended

Action

If there was an unexpected job failure associated with this event, contact your vendor's customer support
for assistance.