CHS-1002

5

CHS Messages

CHS-1002

Message

ki_gd_register_action failed with rc = <return val>.

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates an internal error.

Recommended

Action

To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.

CHS-1003

Message

Slot ENABLED but Not Ready during recovery, disabling slot = <slot number> rval =

<return value>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the slot state has been detected as inconsistent during failover or recovery.

Recommended

Action

For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.

For a non-bladed switch, restart or power cycle the switch.

CHS-1004

Message

Blade attach failed during recovery, disabling slot = <slot number>, rval =

<return value>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified blade has failed during failover or recovery.

Recommended

Action

For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.

For a non-bladed switch, restart or power cycle the switch.