Xtun-2002, Xtun-2003, Xtun-2004 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 973

Advertising
background image

Fabric OS Message Reference

951

53-1003140-01

XTUN-2002

5

Recommended

Action

If the tunnel has not been administratively disabled or deleted, a possible network error or disruption has
occurred.

XTUN-2002

Message

FCIP Tunnel <VE Port (Tunnel) Number> Circuit <Circuit Number> UP.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified circuit is up.

Recommended

Action

No action is required.

XTUN-2003

Message

FCIP Tunnel <VE Port (Tunnel) Number> Circuit <Circuit Number> DOWN (<Reason>).

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified circuit has gone down, and the tunnel will also be down if this is the last circuit
available.

Recommended

Action

If the tunnel or circuit has not been administratively disabled or deleted, a possible network error or
disruption has occurred.

XTUN-2004

Message

FCIP Tunnel <VE Port (Tunnel) Number> <Priority Class>-Pri QoS UP.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified quality of service (QoS) for this tunnel is up. This applies to the data classes
only. When the F-Class comes online, the tunnel itself is marked as up.

Recommended

Action

No action is required.

Advertising