Ccfg messages, Ccfg-1001, Ccfg-1002 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 246: Ccfg-1003
224
Fabric OS Message Reference
53-1003140-01
CCFG-1001
5
CCFG Messages
CCFG-1001
Message
Failed to initialize <module>, rc = <error>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the initialization of a module within the Converged Enhanced Ethernet (CEE) configuration
management daemon has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command.
CCFG-1002
Message
Started loading CEE system configuration.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that the Converged Enhanced Ethernet (CEE) system configuration has started loading.
Recommended
Action
No action is required.
CCFG-1003
Message
System is ready to accept CEE user commands.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that the Converged Enhanced Ethernet (CEE) shell is ready to accept configuration
commands.
Recommended
Action
No action is required.