Hil-1613, Hil-1614, Hil-1615 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 629

Advertising
background image

Fabric OS Message Reference

607

53-1003140-01

HIL-1613

5

HIL-1613

Message

PSU-FAN FRUS Air Flow matched. System shutdown canceled.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the airflows of the power supply and fan assemblies have changed to move in the same
direction. The system continues to operate. This message is applicable only to the Brocade 6510.

Recommended

Action

Ensure that the airflows of the power supply and fan assemblies run in the same direction.

HIL-1614

Message

MISMATCH in Fan airflow direction. Replace FRU with fan airflow in same direction.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the airflow of the fan is in the reverse direction. This may heat up the system.

Recommended

Action

Replace the fan field-replaceable units (FRUs) in such a manner that the air flows in the same direction
as the remaining fans. Refer to the Hardware Reference Manual of your switch for instructions to replace
the fan FRUs.

HIL-1615

Message

MISMATCH in PSU-Fan FRUs airflow direction. Replace PSU with fan airflow in same

direction.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the airflow of the power supply unit (PSU) fan is in the reverse direction. This may heat up
the system.

Recommended

Action

Replace the PSU fan field-replaceable unit (FRU) in such a manner that the air flows in the same
direction as the remaining fans. Refer to the Hardware Reference Manual of your switch for instructions
to replace the PSU fan FRU.