C2-1026

5

C2-1026

Message

S<slot number>,P<port number>(<blade port number>): Faulting F_port due to extra

credit detected:ftx=<ftx> curr_cred=<current credits> actual_cred=<actual

credits>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the device is returning the wrong number of receiver-ready (R_RDY) frames.

Recommended

Action

When this error is observed persistently, replace the device.

C2-1027

Message

Detected credit loss on Peer internal Port of Slot <slot number>, Port <port

number>(<blade port number>) vc_no=<vc number> crd(s)lost=<Credit(s) lost>

complete_loss:<complete credit loss>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that credit loss was detected on the peer port.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

C2-1028

Message

Detected excessive Link resets on the port in a second. Slot <slot number>, Port

<port number>(<blade port number>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the port received excessive link resets from peer port within 1 second and that exceeded
threshold.

Recommended

Action

When this error is observed persistently, change the small form-factor pluggable (SFP) transceiver or the
cable on the peer port to which this port is connected.