Sec-1052, Sec-1053, Sec-1054 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 784

Advertising
background image

762

Fabric OS Message Reference

53-1003140-01

SEC-1052

5

SEC-1052

Message

Invalid input.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.

SEC-1053

Message

Invalid pFCS list <pFCS list>

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds these error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.

SEC-1054

Message

Invalid FCS list length <list length>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.