Trce-1004, Trce-1005, Trce-1006 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 947

Advertising
background image

Fabric OS Message Reference

925

53-1003140-01

TRCE-1004

5

Recommended

Action

Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.

TRCE-1004

Message

Trace dump<slot on which the trace dump occurs> was not transferred because trace

auto-FTP disabled.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that trace dump files have been created on the switch or the specified slot, but the trace dump
files were not automatically transferred from the switch because auto-FTP is disabled.

Recommended

Action

Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.

TRCE-1005

Message

FTP Connectivity Test failed due to error.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the connectivity test to the FTP host failed because of reasons such as a wrong FTP
address, FTP site is down, or network is down.

Recommended

Action

Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.

TRCE-1006

Message

FTP Connectivity Test succeeded to FTP site ' <FTP target configured by users> '.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a connectivity test to the FTP host has succeeded.

Recommended

Action

No action is required.