Em-1073, Em-1134, Em-2003 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 339

Advertising
background image

Fabric OS Message Reference

317

53-1003140-01

EM-1073

5

EM-1073

Message

Blade devices cannot be accessed. The blade in slot <FRU slot number> is being

moved to ABSENT state.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the devices on the blade were not accessible. Blade is being tranisitioned to the ABSENT
state.

Recommended

Action

Reseat or replace the affected blade.

EM-1134

Message

<FRU Id> set to faulty, rc=<return code>.

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified
reason.

Recommended

Action

Reseat the FRU.

Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade by using the slotPowerOff and slotPowerOn commands or have the blade's ejector
switch cycled to run POST and verify that the blade does not have any hardware problems.

If the problem persists, replace the FRU.

EM-2003

Message

<Slot Id or Switch for pizza boxes> has failed the POST tests. FRU is being

faulted.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test (POST). Refer to the
/tmp/post[1/2].slot#.log file for more information on the faults. To view this log file, you must be logged in
at the root level. The ID will be Switch for non-bladed systems.

Recommended

Action

On bladed systems, reseat the specified FRU.

On non-bladed switches, restart or power cycle the switch.

If the problem persists, perform the following actions: