FCR-1057

5

FCR-1057

Message

EX_Port(<port number>) incompatible long distance parameters on link.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the port, which is configured in long distance mode, has incompatible long distance
parameters.

Recommended

Action

Check the port configuration on both sides of the link using the portCfgShow command.

Investigate the other switch for more details. Run the errShow command on the other switch to view the
error log for additional messages.

FCR-1058

Message

Port <port number> isolated due to mismatched configuration parameter;

<segmentation reason>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified port was isolated after segmentation caused by mismatched configuration
parameters or by a domain ID assigned by the principal switch that did not match the insistent domain ID
of this port.

Recommended

Action

Check the switches on both ends of the link for a possible mismatch in switch or port configuration
parameters such as Operating Mode, E_D_TOV, R_A_TOV, Domain ID Offset, and so on.

Run the portCfgExport command to modify the appropriate parameters on the local switch.

Run the appropriate configuration command to modify the switch or port parameters on the remote
switch.

FCR-1059

Message

EX_Port <port number> was disabled due to an authentication failure.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the authentication, which uses the Diffie Hellman - Challenge Handshake Authentication
Protocol (DH-CHAP), failed on the EX_Port.

Recommended

Action

Verify that the shared secrets on both sides of the link match.

Disable and enable the ports by using the portDisable and the portEnable commands to restart
authentication.