Plat-1006, Plat-1007, Plat-1008 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 733

Advertising
background image

Fabric OS Message Reference

711

53-1003140-01

PLAT-1006

5

PLAT-1006

Message

Unknown midplane revision.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the chassis has a midplane whose revision is unknown.

This message occurs only on the Brocade M6505.

Recommended

Action

Install newer firmware in the Chassis Management Controller (CMC).

PLAT-1007

Message

BladeSystem Chassis type is unknown, setting maximum internal port speed to 8Gbps.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the Onboard Administrator (OA) could be running an old version of firmware.

If OA firmware is new enough to support Enclosure Information, then OA failed to send the Enclosure
Information soon enough to allow the internal ports to run at 16 GFC.

This message occurs only on the Brocade 6548.

Recommended

Action

No action is required.

PLAT-1008

Message

BladeSystem Enclosure Information arrived late from OA.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the Onboard Administrator (OA) failed to send the Enclosure Information soon enough to
allow the internal ports to run at 16 GFC.

This message occurs only on the Brocade 6548.

Recommended

Action

Execute the hareboot command, followed by the portdisable and portenable commands to allow
internal ports to run at 16 GFC.