Em-1014, Em-1015, Em-1016 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 325

Advertising
background image

Fabric OS Message Reference

303

53-1003140-01

EM-1014

5

EM-1014

Message

Unable to read sensor on <FRU Id> (<Return code>).

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the environmental monitor (EM) was unable to access the sensors on the specified
field-replaceable unit (FRU).

Recommended

Action

Reseat the FRU. If the problem persists, replace the FRU.

EM-1015

Message

Warm recovery failed (<Return code>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a problem was discovered when performing consistency checks during a warm boot.

Recommended

Action

Monitor the switch. If the problem persists, restart or power cycle the switch.

EM-1016

Message

Cold recovery failed (<Return code>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a problem was discovered when performing consistency checks during a cold boot.

Recommended

Action

Monitor the switch.

If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

Advertising