Swch-1025, Swch-1026, Swch-1027 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 938

Advertising
background image

916

Fabric OS Message Reference

53-1003140-01

SWCH-1025

5

SWCH-1025

Message

This Logical Switch has ports other than 16 Gbps-capable FC ports. Edge Hold Time

for these ports is unchanged and is <Edge Hold Time>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the edge hold time for the non 16 Gbps-capable FC ports is not the same as 16
Gbps-capable FC ports in the logical switch. The non 16 Gbps-capable FC ports use the edge hold time
configured on the default switch.

Recommended

Action

To know the edge hold time configured for non 16 Gbps-capable FC ports, go to the default switch and
execute the configShow command.

SWCH-1026

Message

HA state out of sync: Standby CP (ver = <standby SWC version>) does not support

auto csctl_mode (Active CP version = <active SWC version>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the standby control processor (CP) does not support auto class-specific control (CS_CTL)
mode.

Recommended

Action

Upgrade the standby CP firmware version to same level as active CP.

SWCH-1027

Message

HA state out of sync: Standby CP (ver = <standby SWC version>) does not support

NPIV Base device Logout functionality. (active ver = <active SWC version>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the standby control processor (CP) does not support N_Port ID Virtualization (NPIV) base
device logout functionality, but the switch has some ports with base device configured.

Recommended

Action

Load a firmware version on standby CP that supports NPIV Base device Logout functionality using the
firmwareDownload command, or change the 'base logout' feature with the portCfgNPIVPort
command.

Advertising