Fspf-1012, Fspf-1013, Fspf-1014 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 490

Advertising
background image

468

Fabric OS Message Reference

53-1003140-01

FSPF-1012

5

Recommended

Action

Investigate current ICL configuration to ensure that all recommendations for cabling are satisfied.

FSPF-1012

Message

All existing ICL topology imbalances have been corrected.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the existing inter-chassis link (ICL) configuration that was resulting in an unbalanced
topology has been corrected.

Recommended

Action

No action is required.

FSPF-1013

Message

Exceeded maximum number of supported paths (16) to one or more remote domains.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there are more than 16 (maximum number of paths supported) available shortest cost
paths to reach one or more remote domains. Traffic may be impacted or follow unexpected traffic
patterns.

Recommended

Action

Use the fabricShow -paths, topologyShow, and lsDbShow commands to get additional details about
which remote domains are violating the maximum paths limit. Refer to the Fabric OS Administrator's
Guide
for information on the causes and potential impacts.

FSPF-1014

Message

All previously reported maximum path violations have been corrected.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that all existing violations of the maximum paths limit have been corrected.

Recommended

Action

No action is required.

Advertising