SWCH-1004

5

SWCH-1004

Message

Blade attach failed during recovery, disabling slot = <slot number>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified blade has failed during failover or recovery.

Recommended

Action

For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.

For a non-bladed switch, reboot or power cycle the switch.

SWCH-1005

Message

Diag attach failed during recovery, disabling slot = <slot number>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the diagnostic blade attach operation has failed during failover or recovery.

Recommended

Action

For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.

For a non-bladed switch, reboot or power cycle the switch.

SWCH-1006

Message

HA state out of sync: Standby CP (ver = <standby SWC version>) does not support

NPIV functionality. (active ver = <active SWC version>, NPIV devices = <'1' if

NPIV devices exist; Otherwise '0'>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the standby control processor (CP) does not support N_Port ID Virtualization (NPIV)
functionality, but the switch has some NPIV devices logged in to the fabric.

Recommended

Action

Load a firmware version on a standby CP that supports NPIV functionality using the firmwareDownload
command.