SULB-1023

5

SULB-1023

Message

The blade in slot <Slot number> has rebooted during firmwaredownload.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

WARNING

Probable Cause

Indicates that there may be an error caused by an unexpected disruption of the firmwareDownload
command; for example, powering off and on of the indicated BP blade in the middle of a firmware
download. The error may also be caused by persistent storage hardware failure or by a software error.

Recommended

Action

The firmwareCommit command will be started automatically after the blade boots up to repair the
secondary partition. If at the end of the firmware commit, the blade firmware version is still inconsistent
with the active CP firmware, firmware download will be restarted automatically on the blade. Run the
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.

SULB-1024

Message

Firmware commit has completed on the blade in slot <Slot number>.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

WARNING

Probable Cause

Indicates that the firmwareCommit command has completed on the specified blade.

Recommended

Action

Run the firmwareShow command to verify the firmware versions. If the blade firmware is the same as
the active CP firmware, the firmwareDownload command has completed successfully on the blade.
However, if the firmware commit operation has been started to repair the secondary partition, at the end
of the firmware commit, the blade firmware version may still be inconsistent with the active CP firmware.
In this case, firmware download will automatically be restarted on the blade. Run the
firmwareDownloadStatus command to monitor the progress.