188

Fabric OS Message Reference

53-1003140-01

BL-1031

5

BL-1031

Message

Link timeout in internal port (slot <slot number>, port <port number>) resulted in

blade fault. Use slotpoweroff/slotpoweron to recover the blade.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that link timeout occurred in one of the back-end internal ports.

Recommended

Action

Power cycle the blade using the slotPowerOff and slotPowerOn commands.

BL-1032

Message

(slot <slot number>,bitmap 0x<object control flags(bitmap)>) ports never came up

ONLINE (reason <reason for port disable>, state <status of the blade>). Disabling

slot.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that back-end (non-user) ports have not come online within the time limit.

Recommended

Action

Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch
cycled to run POST and verify that the blade does not have any hardware problems.

If the message persists, replace the blade.

BL-1033

Message

(slot <slot number>,bitmap 0x<object control flags(bitmap)>) No disable

acknowledgment from ports (state <status of the blade>). Disabling slot.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the system has timed out waiting for the disable messages from the user ports after
disabling the ports.

Recommended

Action

Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch
cycled to run POST and verify that the blade does not have any hardware problems.

If the message persists, replace the blade.